To download technical documentation, you need to register with your name and e-mail address. It is very quick and enables you to have access to all documentation on the website.
The following documents match your search:
|
|
| |
| Application |
|
1
|
|
Cost savings with the latest control techology in Ladbergen
|
| |
The WWTP of Ladbergen (Germany) is
one of the top-performing plants of the
region, although the inlet conditions
are extremely difficult with a COD up to
3.000 mg/l. With significant rebuildings,
process instruments by HACH LANGE
and the modern control system Opti-
Nox by KLEINE (engineering office in
Germany) they achieved this position.
In future they are going to save energy
and further reduce wastewater fees.
Author: Uwe Karg, Application process measurement
technology HACH LANGE. 4 pages
|
| |
Date: 2008-10-10
|
919 KB
Download
|
|
|
2
|
|
Aeration control technology with SC 1000
|
| |
Author: Uwe Karg, Application process measurement
technology, HACH LANGE. The WWTP in Harsefeld (northern part of
Germany, 23.000 PE) runs with an aeration
control system based completely on three
relay contacts of a SC 1000. Additionally
an AMTAX sc and a LDO are installed to
provide the measurement values needed
for the 2-point control function regulating
ammonium and oxygen. The result: 20 %
less operating hours of the aeration and
Ntot < 5 mg/l. The plant manager is very
satisfied with this small and well performing
unit and he will keep this system
even after the installation of a PLC or a
complex control system for the plant. 4 pages
|
| |
Date: 2008-07-29
|
952 KB
Download
|
|
|
3
|
|
Telemetry for the highest level of plant reliability
|
| |
Author: Uwe Karg, Diplom-Ingenieur, chemistry, Application process measurement technology, HACH LANGE. Reliability is a main goal for
control processes which have to reduce operating costs or ensure compliance with limit values. WWTP in Radolfzell (40.000
PE) at the Bodensee (Lake Constance) fullfil both requirements. Process measuring instruments supply the control system continuously
with readings and signal their operational readiness by means of telemetry.
Non-compliance with the limit values has been reduced significantly and the
savings in added carbon amount to up to € 8,000 each year. 4 pages
|
| |
Date: 2008-04-22
|
657 KB
Download
|
|
|
4
|
|
Water Quality Monitoring 40 Metres Below the Sea bed
|
| |
Natural groundwater collected around the tunnels operated by Eurotunnel is
continuously monitored before being pumped to the coast and discharged
into the sea. Six multiparameter water quality monitoring systems have been
custom-designed by HACH LANGE to ensure that there is no potential for
harmful water to enter the pipelines. Each monitoring system is connected to a sophisticated data collection and alarm system that is able to divert water into vast underground sumps if alarm conditions occur. To-date, no such emergency has taken place. Commenting on the new monitoring system is the Eurotunnel Senior Technician / Project Manager Michael Edwards and the Eurotunnel maintainance staff. 4 pages
|
| |
Date: 2007-07-31
|
956 KB
Download
|
|
|
5
|
|
LDO, Measuring oxygen levels in trout farms
|
| |
An adequate level of oxygen must be maintained in the water of fish farms.
If the level is too low, fish production suffers. Kirsten and Alexander Tautenhahn have run a trout farm in Germany, since 1991. Oxygen levels at the farm have been monitored by HACH LANGE LDO sensors since July 2005. The accuracy of the measurements, also at high concentrations, ensures optimal oxygen transfer even during the night with no flow around the sensors. The rugged sensor and extensive warranty assure reliable long-term operation.
|
| |
Date: 2007-03-30
|
642 KB
Download
|
|
|
6
|
|
LDO, 80 % less maintenance within paper industry
|
| |
An average of 9.6 litres of wastewater is generated per kilogram of paper in Germany. Several paper mills use biological processes to treat their wastewater. In Neuss, Procter & Gamble (TEMPO paper handkerchiefs, etc.)
has Europe’s biggest factory for paper-based hygiene products. Its biological
wastewater treatment plant became operational in 1994. The aeration control system uses the LDO optical oxygen sensor, which is H2S
resistent and enabled the monthly maintenance time to be reduced by 80 %. 4 pages
|
| |
Date: 2007-03-29
|
614 KB
Download
|
|
|
7
|
|
LDO, A suitable oxygen meter for the aeration tank
|
| |
Practice report about a direct comparison with a conventional O2 probe in which HACH LANGE LDO probe took part in at the sewage treatment plant (Nieuwveer sewage treatment plant, Netherlands) for a period of nine weeks. Author: Jaap van Liebergen, process engineer, Waterschap Brabantse Delta; 4 pages
|
| |
Date: 2006-12-04
|
581 KB
Download
|
|
|
8
|
|
LDO, Optical measurement of oxygen concentration in water
|
| |
Complex summary of advantages of the LDO probe in comparison to electrochemical methods. Detailed description of the technical background of the HACH LANGE LDO probe (Luminescent Dissolved Oxygen) used for determining dissolved oxygen in water. Author: Dr. Michael Häck, Applications specialist for waste-water and process and process measurement technology, HACH LANGE; 8 pages
|
| |
Date: 2006-12-04
|
700 KB
Download
|
|
|
9
|
|
From O2 control to aeriation control with NITRATAX eco sc
|
| |
Practice report wastewater treatment plant Sonsbeck, Niersverband, Germany; Author: Dipl.-Ing. H.-G. Hauser; From O2 measurement to aeriation controll with Nitratax eco; Example of benefits of switching to a nitrate- controlled aeration cycle, costs reduction, lower enegy consumption; Process instruments: NITRATAX eco sc, LDO, SC 100 Controller; 4 pages (digital)
|
| |
Date: 2006-11-02
|
598 KB
Download
|
|
|
10
|
|
LDO process, Sewage Treatment Plant reports success with HACH LANGE LDO
|
| |
Application report about a successful use of HACH LANGE LDO sensor in the aeration control in the Sewage Treatment Plant in Vienna (60 LDO process sensors in SC network). The precise measurement of the oxygen concentration enables very accurate aeration of the activeted sludge and leads to cost savings due to the lower energy consumption for the aeration. Experiences after 18 months of uninterrupted operation, advantages of using SC 1000 controllers. 4 pages
|
| |
Date: 2006-09-25
|
466 KB
Download
|
|
|
11
|
|
NITRATAX ECO / LDO Process AIR CONTROL
|
| |
Aeration control with NITRATAX eco and LDO
|
| |
Date: 2005-09-23
|
227 KB
Download
|
|
|
12
|
|
SBR REACTORS (SEQUENCING BATCH REACTORS)
|
| |
Process optimisation of sequencing batch reactors with process measurement technology
|
| |
Date: 2005-08-22
|
319 KB
Download
|
|
|
13
|
|
LDO Process in the water industry
|
| |
UK water industry gives LDO the thumbs up; Operators from 7 water companies have used the LDO over the past months and give their opionion; 4 pages (digital version only)
|
| |
Date: 2004-08-20
|
419 KB
Download
|
|
|
14
|
|
Measurement of dissolved oxygen in industrial waste water
|
| |
The concentration of dissolved oxygen is used to monitor, control and automate the oxygen transfer into the aeration tank
|
| |
Date: 2004-02-04
|
178 KB
Download
|
|
| Information |
|
15
|
|
SC 100 / SC 1000, controller
|
| |
SC controller: One for all; The standard platform for all probes and analysers
Abstract: SC 100 / SC 1000, benefit of the technology, principle, modification for all probes, SC network, technical data, order information; 12 pages
|
| |
Date: 2009-01-16
|
1.86 MB
Download
|
|
|
16
|
|
LDO Application Report - Proven in Practice
|
| |
LDO (Luminescent Dissolved Oxygen) technology has revolutionised the measurement of oxygen in water and wastewater. Since their launch by HACH LANGE, optical LDO probes have displaced membranebased
electrochemical sensors.
|
| |
Date: 2008-11-13
|
515 KB
Download
|
|
|
17
|
|
Services: Certificate of Guarantee LDO
|
| |
Services: Certificate of Guarantee LDO
|
| |
Date: 2007-01-05
|
56.0 KB
Download
|
|
|
18
|
|
LDO, Dissolved oxygen process probe
|
| |
Proven method of dissolved oxygen measurement with HACH LANGE LDO probe. Successfully in use since 2003, revolutionary method for continuous O2-measurement; principle, benefits, applications (including use in the WWTP Vienna), technical data; 4 pages
|
| |
Date: 2006-11-29
|
1.94 MB
Download
|
|
| Software |
|
19
|
|
Software: Available EDD (Electronic Device Description) files for SI792 2-wire transmitter
|
| |
Available EDD files for SI792 (SI792 Profibus PA) 2-wire Transmitter (use of Simatic PDM 6.0)
|
| |
Date: 2008-07-16
|
126 KB
Download
|
|
|
20
|
|
Software: Available EDD (SC100) files SIMATIC PDM V6.0
|
| |
Software: Available EDD (Electronic Device Description) files for SC 100 (SIMATIC PDM V6.0)
|
| |
Date: 2008-07-16
|
854 KB
Download
|
|
|
21
|
|
Software: Available GSD files for SI792 2-wire transmitter
|
| |
Available GSD files for SI792 (SI792PA) 2-wire Transmitter (Profibus)
|
| |
Date: 2008-07-16
|
2.16 KB
Download
|
|
|
22
|
|
Software: Available EDD (SC 1000) files SIMATIC PDM V6.0
|
| |
Available EDD (Electronic Device Description) SC 1000 files for SIMATIC PDM V6.0
|
| |
Date: 2008-07-10
|
1.13 MB
Download
|
|
| Technical documents |
|
23
|
|
Datasheet: LDO Flow Through Assembly
|
| |
Datasheet: LDO Flow Through Assembly
|
| |
Date: 2008-11-01
|
127 KB
Download
|
|
|
24
|
|
Instruction Sheet: LDO Air Blast Head, Guard Head Installation
|
| |
• New improved Air Blaster Cleaning Head and Guard Head for LDO® now available for ordering
• Part numbers in PIB; instructions attached
|
| |
Date: 2007-07-27
|
214 KB
Download
|
|
|
25
|
|
Instruction Sheet: LDO Flow Cell
|
| |
Instruction Sheet: LDO Flow Cell
|
| |
Date: 2007-05-01
|
265 KB
Download
|
|
|
26
|
|
Ohjelehti: LDO läpivirtausastia, FINNISH LANGUAGE
|
| |
Ohjelehti: LDO läpivirtausastia, FINNISH LANGUAGE
|
| |
Date: 2007-05-01
|
276 KB
Download
|
|
|
27
|
|
Installation instructions tank rim mount for LDO process and E-Chem Sensors
|
| |
Overview from installation kits.
|
| |
Date: 2006-02-15
|
3.33 MB
Download
|
|
|
28
|
|
Manual sc100
|
| |
Manual sc100
|
| |
Date: 2005-08-16
|
1.83 MB
Download
|
|
|
29
|
|
Manual: LDO
|
| |
Manual: LDO
|
| |
Date: 2005-04-01
|
341 KB
Download
|
|
|
30
|
|
Mounting instruction 1 LDO Process
|
| |
Mounting instruction 1 LDO
|
| |
Date: 2004-08-19
|
288 KB
Download
|
|
| |
|
|